    HLF4 load cell

    Features And Uses

    ●Stainless steel
    ●Widely used in presses, hydraulic presses, testing machines, hopper scales and various industrial force measuring and weighing systems
    Online Service
    Dimensions

    Capacit

    A

    B

    B1

    C

    D

    F

    M

    1-101053734896.532M16X1.5
    15-251255646101.88.639M30X1.5
    30-501456554116.810.560M40X1.5
    60-100205857316212.576M60X2

    150-200

    29612511524621148M110X3
    Technical Parameter

    Capacity

    1-200t

    Accuracy class0.05%F.S.
    Rated output2.0±10%(0.1%)mV/V
    Zero balance±2%F.S.
    Non-linearity±0.05%F.S.
    Hysteresis±0.05%F.S.
    Repeatability±0.05%F.S.
    Creep(30min)±0.05%F.S.
    Temp.effect on output±0.05%F.S./10°C
    Temp.effect on zero±0.05%F.S./10°C
    Input impedance750±50Ω
    Output impedance700±5Ω
    Insulation≥5000MΩ(50VDC)
    Recommended excitation5~10VDC
    Maximum excitation15VDC
    Compensated temp. range-10~40°C
    Operation temp. range-20~60°C
    Safe overload150%F.S.
    Ultimate overload200%F.S.
    Cable sizeΦ5.6x10m
    Portection class

    IP65

    Force Direction




    Wiring Diagram


    Hotline

    0755-89492755

    Email :ivy@szchq.com

    Fax:0086- 755-89492700

    Headquarters address:Room No.1211, tongfang centre building, xiner community, xinqiao street, baoan district, Shenzhen city, guangdong province

    Factory address:8th floor one building, NO.2 shadimen street, dalingshan town, dongguan city ,guangdong province